4. AT Command Set and S-Registers

Table 4-3

(16 of 20)

Model 3830 S-Registers

S77 DTR Alarm Reporting

Register determines whether an alarm is sent to the 6800 Series Network Management System controller when the DTR signal has been Off for more than 10 seconds.

Register has the following values:

0 = Disable

1 = Enable

S78 V.32bis Automode (Dial Line)

If enabled, automode permits the modem to automatically connect to a remote modem using any supported modulation scheme.

If disabled, the modem only supports the modulation scheme selected by the S41 register (Dial-Line Rate).

If the modem is in a modem pool attached to a System 85 Private Branch Exchange (PBX), S78 should be set to 2. This modifies parameters used during connection to the PBX.

Register has the following values:

0 = Enable

1 = Disable

2 = System 85

Factory setting is Enable.

3830-A2-GB91-30

August 1998

4-45

Page 81
Image 81
Paradyne manual Model 3830 S-Registers S77  DTR Alarm Reporting, S78  V.32bis Automode Dial Line