4. AT Command Set and
Table
(20 of 20)
Model 3830 S-Registers
S91 Cellular Enhancements
Valid only if Enhanced Throughput Cellular (ETC) is installed. Register determines whether parameters are set to improve performance over a cellular link. Should be enabled when the remote modem is using a cellular connection.
Register has the following values:
0 = Disable
1 = Enable
Factory setting is Disable; &F5 and &F6 set S91 to Enable.
S93 RJ11 Cellular Adapt
Valid only if Enhanced Throughput Cellular (ETC) is installed. Register controls support for an RJ11 connection, including generation of the ETC 1.1 Calling Tone during call origination.
0 = Disable
1 = Enable
Factory setting is Disable.
August 1998 |