COMSPHERE 3800 Series Modems ± Model 3830

Table 4-3

(17 of 20)

Model 3830 S-Registers

S80 No Data Disconnect Trigger Signal

Register determines whether Pin 2 (transmit data) or Pin 3 (receive data) of the modem's EIA-232 serial interface is monitored so that the modem can disconnect the call if there is no activity for a certain period. (See the \T command.)

Register has the following values:

0 = Transmit or Receive

1 = Transmit only

2 = Receive only

3 = Transmit and Receive

Factory setting is 3.

S81 Leased Line Signal Quality Retrain

Forces the modem to retrain if the SQ (Signal Quality) LED is on for more than the specified number of seconds (1±5). SQ Retrain reduces the amount of bad data sent to the DTE when no error control is used, but greatly increases the likelihood of retrains on impaired lines. SQ Retrain affects only V.32 and V.32bis modulations.

Register has the following values:

0= Disable

1±5 = Number of seconds of poor signal quality before retrain Factory setting is Disable.

S82 V.32bis Autorate (Leased Line)

Determines if the Autorate function is used on leased lines when connected in V.32bis mode. Autorate allows the modem to adjust line speed due to noise.

Register has the following values:

0 = Enable

1 = Disable

Factory setting is Enable.