COMSPHERE 3800 Series Modems ± Model 3830
Table
(17 of 20)
Model 3830
S80 No Data Disconnect Trigger Signal
Register determines whether Pin 2 (transmit data) or Pin 3 (receive data) of the modem's
Register has the following values:
0 = Transmit or Receive
1 = Transmit only
2 = Receive only
3 = Transmit and Receive
Factory setting is 3.
S81 Leased Line Signal Quality Retrain
Forces the modem to retrain if the SQ (Signal Quality) LED is on for more than the specified number of seconds (1±5). SQ Retrain reduces the amount of bad data sent to the DTE when no error control is used, but greatly increases the likelihood of retrains on impaired lines. SQ Retrain affects only V.32 and V.32bis modulations.
Register has the following values:
0= Disable
1±5 = Number of seconds of poor signal quality before retrain Factory setting is Disable.
S82 V.32bis Autorate (Leased Line)
Determines if the Autorate function is used on leased lines when connected in V.32bis mode. Autorate allows the modem to adjust line speed due to noise.
Register has the following values:
0 = Enable
1 = Disable
Factory setting is Enable.
August 1998 |