Paradyne manual Model 3830 AT Commands Tn  Tests

Models: 3830

1 138
Download 138 pages 42.35 Kb
Page 57
Image 57

4. AT Command Set and S-Registers

Table 4-2

(15 of 23)

Model 3830 AT Commands

&Tn Tests

&T0 Abort. Stops any test in progress.

&T1 Local Analog Loop.

&T2 Pattern. Transmits and receives a 511 Bit Error Rate Test (BERT).

*&T3 Local Digital Loopback test.

&T4 Enables Receive Remote Loopback Response configuration option.

&T5 Disables Receive Remote Loopback Response configuration option.

*&T6 Remote Digital Loopback test.

*&T7 Remote Digital Loopback with Pattern.

&T8 Local Loopback with Pattern.

&T9 Self-Test.

To start a test, set the S18 register to a desired test duration in seconds (for example, 30 seconds), and then issue the &T command. Test results display as the number of errors sent or received over the number of blocks sent or received.

*The modem must be online and in Direct mode for this test to work properly.