Paradyne manual Model 3830 S-Registers S43  V.32bis Train, S44  Leased-Line Rate

Models: 3830

1 138
Download 138 pages 42.35 Kb
Page 73
Image 73

4. AT Command Set and S-Registers

Table 4-3

(8 of 20)

Model 3830 S-Registers

S43 V.32bis Train

Register controls the modem's train time for V.32bis/V.32 mode.

Register has the following values:

0 = Long (A long train is required for satellite links which have long roundtrip delays.)

1 = Short

Factory setting is Long.

S44 Leased-Line Rate

Determines the modem's highest data rate and modulation scheme for operation on 2-wire leased lines in either Answer or Originate mode.

Register has the following values:

0 = 14,400 (V.32bis)

1 = 14,400 (V.32bis)

2 = 12,000 (V.32bis)

3 = 9600 (V.32bis)

4 = 7200 (V.32bis)

5 = 4800 (V.32bis)

6 = 2400 (V.22bis)

18 = 19,200 (V.32terbo)

19 = 16,800 (V.32terbo)

Factory setting is 19,200 (V.32terbo).

S45 Leased Line Transmit Level

Level Determines the modem's transmit power output level over leased lines.

Enter a value from 0±15 dBm.

Factory setting is 0 dBm.

3830-A2-GB91-30

August 1998

4-37

Page 73
Image 73
Paradyne manual Model 3830 S-Registers S43  V.32bis Train, S44  Leased-Line Rate, S45  Leased Line Transmit Level