| A. Troubleshooting |
|
| Table |
|
| (2 of 4) |
| Modem ± VF Connection | |
|
|
|
Symptom |
| Action |
|
|
|
Modem goes |
| Verify that originating modem supports your |
answers, but does not |
| modem's modulation schemes. The 3830 |
connect (continued) |
| modem recognizes V.32terbo, CCITT V.32bis, |
|
| V.32, V.22bis, V.22, V.21, Bell 212A, and Bell |
|
| 103J. The 3800 Series modem does not |
|
| support other vendors' proprietary modulation |
|
| schemes. |
|
| Use the S41 register to force your modem to |
|
| operate at the same modulation scheme as |
|
| the originating modem. |
|
|
|
Originate Mode |
| Verify that the modem's DTE Dialer |
|
| configuration option is set to the correct |
|
| setting: either AT, DTR Dialing, |
|
| V.25bis Async, V.25bis Bisync, or |
|
| V.25bis HDLC. |
|
|
|
Modem does not go |
| If using AT Dialing, refer to the Table |
| Modem Ð DTE Connection . | |
dialing |
| If using DTR Dialing, verify the telephone |
|
| |
|
| number stored in directory location 1, and |
|
| verify that the DTE is raising DTR from Off to |
|
| ON to initiate a dial. |
|
| If using V.25bis Async, verify that the correct |
|
| |
|
| character format is set to 7 data bits with even |
|
| parity and 1 stop bit, and the carriage return |
|
| and line feed are used as command |
|
| terminators. |
|
| If using V.25bis Bisync, verify that the correct |
|
| |
|
| character format uses two synchronous control |
|
| characters and a |
|
| before the text block and an |
|
| character after the text block. |
|
|
|
August 1998 |