12C Diagnostics

What can be seen?

The I2C diagnostics menu gives an overview of the I2C failures inside the projector. To scroll through the failure list, push the cursor key or .

The I2C address, IC number and module name will be given in I2C diagnostic menu. When no errors are detected, the following message will appear on the screen:

"No errors on i2c-bus detected".

How to select?

1.Push the cursor key or to highlight 'I²C Diagnostics' (menu 1).

2.Press ENTER to display the diagnostic menu (menu 2).

SERVICE MODE

PROJECTOR SET-UP

MEMORY MANAGEMENT

COMMON SETTINGS

I2C DIAGNOSTICS

VOLTAGE DIAGNOSTICS

PROJECTOR DIAGNOSTICS

Select with or then <ENTER>

<EXIT> to return

menu 1

 

I2C DIAGNOSTICS

 

Failures :

 

addr

IC number

mod.name

48H

IC200

DECODER

Select with or then <ENTER>

<EXIT> to return

menu 2

Voltage Diagnostics

What can be seen?

The real value of the different voltages will be displayed on the voltage diagnostics menu.

How to start up?

1.Push the cursor key or to highlight 'Voltage diagnostics' (menu 1).

2.Press ENTER to display the voltage diagnostic menu (menu 2).

SERVICE MODE

PROJECTOR SET-UP

MEMORY MANAGEMENT

COMMON SETTINGS

I2C DIAGNOSTICS

VOLTAGE DIAGNOSTICS

PROJECTOR DIAGNOSTICS

Select with or then <ENTER>

<EXIT> to return

menu 1

VOLTAGE DIAGNOSTICS

+17V

:

16.9 Volt

-17V

:

-17.1 Volt

+9V

:

+9 Volt

+12V

:

+11.9 Volt

-12V

:

-11.8 Volt

+30V

:

+29.8 Volt

-40V

:

-39.8 Volt

+110V

:

+110 Volt

+210V

:

+209 Volt

HTHD

:

 

-conv

:

 

+conv

:

 

foc_lo

:

 

foc_hi

:

 

<EXIT> to return.

menu 2

76

Page 78
Image 78
Runco DTV-1200 owner manual 12C Diagnostics, Voltage Diagnostics, I2C Diagnostics, Decoder