Technical data of CPU 31xC 6.2 CPU 312C

Technical data

Functionality

 

MPI

Yes

PROFIBUS DP

No

Point-to-point communication

No

MPI

 

 

Services

 

PG/OP communication

Yes

Routing

No

Global data communication

Yes

S7 basic communication

Yes

S7 communication

Yes

 

As server

 

As client

No

 

 

Transmission rates

max. 187.5 kbps

Programming

 

Programming language

LAD/FBD/STL

Available instructions

see the Instruction List

Nesting levels

8

System functions (SFCs)

see the Instruction List

System function blocks (SFBs)

see the Instruction List

User program security

Yes

Integrated I/O

 

Default addresses of the integrated

124.0 to 125.1

 

Digital inputs

 

Digital outputs

124.0 to 124.5

 

 

Integrated functions

 

Counters

2 channels (see the Manual Technological

 

 

 

Functions)

Frequency counters

2 channels, max. 10 kHz (see the Manual

 

 

 

Technological Functions)

Pulse outputs

2 channels for pulse width modulation, max.

 

 

 

2.5 kHz (see the Manual Technological

 

 

 

Functions)

Controlled positioning

No

Integrated "Controlling" SFB

No

Dimensions

 

Mounting dimensions W x H x D (mm)

80 x 125 x 130

Weight

 

409 g

Voltages and currents

 

Power supply (rated value)

24 VDC

Permitted range

20.4 V to 28.8 V

Current consumption (no-load operation)

Typically 60 mA

Inrush current

Typically 11 A

Power consumption (nominal value)

500 mA