Siemens S7-300 appendix Standard Interrupt Count Posi-1 Input Tioning

Models: S7-300

1 244
Download 244 pages 25.52 Kb
Page 140
Image 140

Technical data of CPU 31xC

6.6 Technical data of the integrated I/O

CPU 313C, CPU 313C-2 DP/PtP, CPU 314C-2 DP/PtP: DI/DO (connectors X11 and X12)

X11 of CPU 313C-2 PtP/DP

X12 of CPU 314C-2 PtP/DP

Standard

DI

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

Interrupt

Count

Posi-1)

input

 

tioning

X

Z0 (A)

A 0

 

X

Z0 (B)

B 0

 

X

Z0 (HW gate)

N 0

 

X

Z1 (A)

Prob 0

X

Z1(B)

Bero

0

X

Z1 (HW gate)

 

 

X

Z2 (A)

 

 

X

Z2 (B)

 

 

X

Z2 (HW gate)

 

 

X

Z3 (A)

 

 

X

Z3 (B)

1)

 

X

Z3 (HW gate)

 

 

X

Z0 (Latch)

 

 

X

Z1 (Latch)

 

 

X

Z2 (Latch)

 

 

X

Z3

1)

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

 

 

 

Positioning 1)

Count

Standard

1L+

2L+

21

Digital Analog

 

DO

DI+0.0

DO+0.0

22

 

V0

X

DI+0.1

DO+0.1

23

 

V1

X

DI+0.2

DO+0.2

24

 

V2

X

DI+0.3

DO+0.3

25

 

V3 1)

X

DI+0.4

DO+0.4

26

 

 

X

DI+0.5

DO+0.5

27

 

 

X

DI+0.6

DO+0.6

28

CONV_EN

 

X

DI+0.7

DO+0.7

29

CONV_DIR

 

X

 

2M

30

 

 

 

 

3L+

31

 

 

 

DI+1.0

DO+1.0

32

R+

 

X

DI+1.1

DO+1.1

33

R-

 

X

DI+1.2

DO+1.2

34

Rapid

 

X

DI+1.3

DO+1.3

35

Creep

 

X

DI+1.4

DO+1.4

36

 

 

X

DI+1.5

DO+1.5

37

 

 

X

DI+1.6

DO+1.6

38

 

 

X

DI+1.7

DO+1.7

39

 

 

X

1M

3M

40

 

 

 

Zn

Counter n

A, B

Encoder signals

HW gate

Gate control

Latch

Store counter distance

Vn

Comparator n

Prob 0

Measuring probe 0

Bero 0

Reference point switch 0

R+, R-

Directional signal

Rapid

Rapid traverse

Creep

Creep speed

CONV_EN

Power section enable

CONV_DIR

Directional signal (only with control type "voltage 0 to 10 V or current from 0 to 10 mA and directional signal")

X

Pin usable if not assigned to technology functions

1) CPU 314C-2 only

Reference

Details are found in the Manual Technical Functions under Counting, Frequency Measurement and Pulse Width Modulation

6-30

CPU 31xC and CPU 31x, Technical data

Manual, Edition 08/2004, A5E00105475-05

Page 140
Image 140
Siemens S7-300 appendix Standard Interrupt Count Posi-1 Input Tioning