When IMMED. CAP. is set to OFF

V-SYNC

0

1

6

7

8

 

 

 

 

Captured image

Remote

 

 

 

 

vRP

 

 

 

 

 

control pulse

 

tRPE

 

 

 

signal

 

 

tRPW

 

 

Notation Parameter

MIN TYP MAX Unit

Remarks

tRPE

Time within

3

12

msec

 

which a

 

 

 

 

 

 

remote control

 

 

 

 

 

 

pulse should

 

 

 

 

 

 

be cleared to

 

 

 

 

 

 

zero.

 

 

 

 

 

tRPW

Length of a

100 –

msec

 

remote control

 

 

 

 

 

 

pulse.

 

 

 

 

 

 

 

 

 

 

 

VRP

Amplitude of a –

5

V

This value

 

remote control

 

 

 

 

is based

 

pulse.

 

 

 

 

on TTL

 

 

 

 

 

 

standards.

 

 

 

 

 

 

 

The above example shows that the images at the seventh and eighth positions are captured. However, images at another positions could be captured depending on the printer mode and printer settings.

Note

When AUTO LIVE of the FUNCTION SETUP menu is set to OFF, the memory image is displayed on the screen after the image is captured in memory. In such a case, whenever you capture an image, press the SOURCE/MEMORY button so that the source image appears on the video monitor. Displaying the memory image does not allow you to capture the image with the correct timing.

When IMMED. CAP. is set to ON

V-SYNC

0

1

2

3

8

 

 

Captured image

 

 

Remote

 

 

 

 

vRP

control pulse

 

tRPE

 

 

 

signal

 

tRPW

 

 

 

 

 

 

 

 

 

 

 

Notation Parameter

MIN TYP MAX Unit

Remarks

tRPE

Time within

3

10

msec

 

which a

 

 

 

 

 

 

remote control

 

 

 

 

 

 

pulse should

 

 

 

 

 

 

be cleared to

 

 

 

 

 

 

zero.

 

 

 

 

 

tRPW

Length of a

100 –

msec

 

remote control

 

 

 

 

 

 

pulse.

 

 

 

 

 

 

 

 

 

 

 

VRP

Amplitude of a –

5

V

This value

 

remote control

 

 

 

 

is based

 

pulse.

 

 

 

 

on TTL

 

 

 

 

 

 

standards.

Note

This mode is effective only when the source image is displayed on the monitor screen. If the memory image is displayed, the image will not be captured even if the pulse is sent to the printer. Be sure to display the source image when sending the pulse.

CAPTURE timing pulse for REMOTE 3

Input equivalent circuit

5V

10K

FL 33

Output equivalent circuit

FL

Others 127