Sun Microsystems 60 service manual Table C-5Supported Hard Drives

Models: 60

1 262
Download 262 pages 16.31 Kb
Page 218
Image 218

TABLE C-4Diskette Drive Signals and Functions (Continued)

Signal Name

Function

 

 

TRACK0

When active low, TRACK0 indicates that

 

the track zero sensor has been activated and

 

that the heads are over the outermost

 

cylinder.

WRITE_PROTECT

When active low, WRITE_PROTECT

 

indicates that the inserted diskette is write-

 

protected and that drive write operations

 

are disabled.

READ_DATA

When active, READ_DATA enables data

 

from the disk to be transferred to the host

 

through this signal line.

HEAD_SELECT

When low, HEAD_SELECT selects head 1.

 

When high, HEAD_SELECT selects head 0.

DISK_CHANGE

When low, DISK_CHANGE indicates that

 

the drive tape medium has been changed.

 

DISK_CHANGE is reset when a new disk is

 

inserted and an enable signal is sent by the

 

host.

 

 

C.1.8.3 Hard Drives

The system unit supports two SCSI hard drive capacities: 4.2-Gbyte and 9.1-Gbyte. The 4.2-Gbyte hard drive is of the 1-inch form factor. The 9.1-Gbyte hard drive is of the 1.6-inch form factor. All hard drives have a single connector configuration. A drive bracket is used to mount the drive. TABLE C-5lists the supported hard drives. The 4.2-Gbyte Disk Drive Specifications, part number 802-7744, provides installation instructions, power requirements, and performance data for the 4.2-Gbyte disk drive. The 9-Gbyte Disk Drive Specifications, part number 802-7745, provides installation instructions, power requirements, and performance data for the 9.1-Gbyte disk drive.

TABLE C-5Supported Hard Drives

Form Factor

 

 

 

 

Dimension

Disk Drive Capacity

Wide

RPM

Seek Time

1.00-inch

4.2 Gbyte

Yes

7200

9.5 ms

(2.54 cm)

 

 

 

 

1.63-inch

9.1 Gbyte

Yes

7200

9.5 ms

(41.3 cm)

 

 

 

 

 

 

 

 

 

C-18Sun Ultra 60 Service Manual • August 2001