Library with
1.Library number (always 0)
2.Library module number 1 (top of rack) through 5 (bottom of rack)
3.Row number 1 through 8 (Base Module) or 1 through 10 (expansion module)
4.Column number 1 through 9 for Base Module and Drive Expansion Module, 1 through 11 for Cartridge Expansion Module
See
Mixed-Media Storage Cell and Drive Capacities
Note – Your software might conflict with the following information. Refer to your software publication for unique information.
TABLE
Note – Do not install an EZ DEM below an original CEM. This is not physically allowed.
Note – The following notes are factors that influence capacity:
1.When you add an expansion module below an existing module, you increase the capacity of the module directly above it by:
■Base module: +14 storage cells
■CEM (when another CEM is below it): +10 storage cells
■DEM: +7 storage cells
2.When a CEM is installed below a Base Module or DEM, the top two rows on columns 9, 10, and 11 of the CEM are not accessible
3.The lowest module in the rack requires installation of the floor. The floor limits the distance the robot can travel, which makes the bottom row(s) in the lowest module inaccessible:
■Base module:
■DEM:
■CEM (below another CEM):
■CEM (below Base Module or DEM):
4.Cartridge access ports:
■Base module: 4 storage cells (one magazine)
■Each DEM: 8 storage cells (two magazines)
■Each CEM: 8 storage cells (two magazines)