Drive Cleaning Tasks
96116 • Revision: KA Chapter 3 SL500 Automated Library Operations 107
Enter Cleaning or Diagnostic Cartridges
Use this procedure to enter new cleaning or diagnostic cartridges to the library through
a CAP. The cartridges will be inserted into system cells.
Before beginning this procedure, verify that all the following conditions are met:
The required number of reserved cells are empty.
The CAP Prevent/Allow state is set to Allow (see your SCSI Reference Manual for
syntax).
The CAP does not contain any data cartridges.
1. Select Tools > Diagnostics.
2. Expand the CAP Folder, highlight the CAP and then select the Import/Export tab.
3. Select “Import Cleaning/Diagnostic cartridges” and then select the Start button from
the Options Bar.
4. The library controller opens the CAP door and the CAP Open LE D is turned on.
5. Grip the handle of the magazine and slide it out of the CAP and onto the door.
Note – To help slide the magazine back into the CAP, do not remove the magazine
from the door. Instead, leave the magazine on the CAP door rails.