Sun Microsystems V880, V890 manual Setenv ttya-ignore-cd false reset, Cms/install/bin/abcadm -k

Models: V890 V880

1 208
Download 208 pages 58 Kb
Page 155
Image 155

Using the remote console

Method 1: from the remote console : To redirect control of the console port from the remote console back to the local console:

1.Do one of the following:

If the system is in UNIX, enter the following commands at the remote console: eeprom output-device=screen

eeprom input-device=keyboard eeprom ttya-rts-dtr-off=true eeprom ttya-ignore-cd=false /usr/sbin/shutdown -y -i6 -g0

If the system is in OpenBoot mode, enter the following commands at the remote console:

setenv output-device screen setenv input-device keyboard setenv ttya-rts-dtr-off true

setenv ttya-ignore-cd false reset

The following occurs:

The system begins to shut down.

Shutdown, reset, and reboot messages are displayed on the remote console.

When the system starts to come back up, the system boot diagnostics are displayed on the local console.

The login screen is displayed on the local console.

2.At the remote console, hang up the modem connection.

3.Log in to the system as root at the local console.

4.To see what is on the ttya port, enter:

/cms/install/bin/abcadm -k

5.To start a port monitor on ttya, enter:

/cms/install/bin/abcadm -i -b 9600 ttya

Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting

May 2006 155

Page 155
Image 155
Sun Microsystems V880 Setenv ttya-ignore-cd false reset, Cms/install/bin/abcadm -k, To start a port monitor on ttya, enter