Maintaining disk drives

6.Holding the drive by its handle, fit the drive into the guide rails at the top and bottom of the drive bay. See the following figure.

7.Slide the drive into the bay until it barely contacts the backplane.

8.Press carefully on the center of the drive. The drive handle begins to close as the drive engages its backplane connector.

9.Press the handle toward the drive until the latch closes, securing the drive in place.

10.Press Enter.

A message similar to the following is displayed:

Waiting for Loop Initialization to complete...

New Logical Nodes under /dev/dsk and /dev/rdsk : c1t2d0s0

c1t2d0s1

c1t2d0s2

c1t2d0s3

c1t2d0s4

c1t2d0s5

c1t2d0s6

c1t2d0s7

No new enclosure(s) were added!!

Note:

Ignore the message No new enclosure(s) were added!!.

Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting

May 2006 117

Page 117
Image 117
Sun Microsystems V880, V890 manual Ignore the message No new enclosures were added