Troubleshooting

Disk drive status indicators

The disk fault LED on the system status and control panel indicates the general status of the disk subsystem. The disk fault LED lights when a fault is detected in the disk subsystem. LEDs inside the system indicate the fault status of individual disk drives.

There are three LEDs (Activity, Fault, OK-to-remove) for each disk drive. The disk drive LEDs are located on the front of the disk cage, as shown below.

The disk drive LEDs are defined as follows:

Name

Icon

LED function

 

 

 

Activity

 

Blinks slowly while the disk drive is being tested,

 

 

configured, or unconfigured during a hot-plug operation.

 

 

Blinks rapidly as the disk drive spins up or spins down.

 

 

Stays lit when the disk drive is at speed and operating

 

 

normally but experiencing no read or write activity. Blinks

 

 

rapidly and irregularly in response to disk read or write

 

 

activity.

 

 

 

Fault

 

Lights when the disk drive encounters a fault.

 

 

 

OK-to-remove

 

Lights when it is safe to remove the disk drive during a

 

 

hot-plug operation.

 

 

Blinks (under software control) to direct attention to a

 

 

disk drive.

 

 

 