Replacing a power supply

Replacing a power supply

In normal conditions, a power supply can be replaced without shutting down the system. However, a power supply must always occupy bays 0 and 1. If a power supply in bay 0 or 1 fails, you must leave the failed power supply in its bay until you are able to install a functioning replacement power supply. A failed power supply in bay 0 or 1 continues to act as an air baffle, channeling airflow to cool the bottom row of disk drives in the disk cage. Replace the failed power supply as soon as possible to regain power redundancy.

!WARNING:

You cannot interchange power supplies between a V880 and V890 computer.

To replace a power supply:

1.Identify the power supply that you want to remove. See Power supply status indicators on page 181 for information about diagnosing power supplies.

2.Release the AC power cord from the strain-relief tie-wrap on the power supply. Press the tab on the head of the tie-wrap to release it. See the following figure.

3. Unplug the AC power cord from the power supply.

Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting

May 2006 145

Page 145
Image 145
Sun Microsystems V880, V890 manual Replacing a power supply