Maintenance

Required references

You need access to the following documents to do the disk maintenance procedures:

The CMS software installation, maintenance, and troubleshooting document for your CMS release

Sun Fire 880 Server Service Manual or Sun Fire V890 Server Service Manual at the Sun documentation Web site:

http://docs.sun.com

Replacing disk drives

The procedures for replacing disk drives is different for the following scenarios:

Replacing a single boot disk: If at least one of the boot disk drives (primary or mirror) is in operation, you can hot-plug a replacement boot disk drive without turning off the system. See Replacing a single boot disk or replacing data disks on page 99.

Replacing data disk drives: When replacing one or more data disk drives, you can hot-plug the replacement disk drives without turning off the system. See Replacing a single boot disk or replacing data disks on page 99.

Replacing both boot disks: If both boot disk drives are defective, you must shut down and turn off the system before replacing the disk drives. See Replacing both boot disks on page 105.

After replacing the disk drives, continue with Setting up the disk drives on page 109.

98 Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting

May 2006

Page 98
Image 98
Sun Microsystems V890, V880 manual Required references, Replacing disk drives