Troubleshooting

Troubleshooting disk drives and DVD drives

This section describes the symptoms of disk drive and DVD drive failures and suggests solutions to correct the problem.

Symptom: The operating system reports a disk drive read, write, or parity error or reports a DVD drive read error or parity error.

Solution: Replace the drive that is indicated in the failure message. The operating system identifies the internal drives as shown in the following table.

Operating

Drive physical location and target

system address

 

 

 

c1t<X>d0s0

Disk drive, target <X> (<X> represents the target

 

number and slot number, 0 to 5)

 

 

c0t6d0s0

DVD drive, target 6

 

 

Symptom: The disk drive fails to respond to commands.

Solution: To test the disk drives:

1.Enter:

/usr/sbin/shutdown -y -i0 -g0

The system shuts down.

2.At the ok prompt, enter the following commands: setenv auto-boot? false

reset-all

The system resets.

3.Enter: probe-scsi

The program displays a message that is similar to the following:

LiD HA LUN

--- Port WWN ---

-----Disk description -----

0

0

0

21000004cf72f08f

SEAGATE ST373405FSUN3660438

1

1

0

21000004cf721553

SEAGATE ST373405FSUN3660438

2

2

0

21000004cf7213ea

SEAGATE ST373405FSUN3660438

6

6

0

508002000016b5b1

SUNW

SUNWGS INT FCBPL9224

3

3

0

21000004cf72114b

SEAGATE

ST373405FSUN3660438

4

4

0

21000004cf7211ae

SEAGATE

ST373405FSUN3660438

5

5

0

21000004cf7214a3

SEAGATE

ST373405FSUN3660438

186 Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting

May 2006

Page 186
Image 186