Symmetricom SNMP Enterprise MIB | Appendix D: SNMP – Simple Network Management Protocol |
actsBaudRate OBJECT-TYPE SYNTAX INTEGER
{
baud300 (300), baud1200 (1200),
baud9600 (9600),
}
MAX-ACCESS read-only STATUS current
DESCRIPTION
“Indicates the baud rate setting for the ACTS modem. The ACTS dial-up service accepts 300 or 1200 baud. Note: this is a rare case where faster is not better and 300 baud yields the best time accuracy.” ::= { acts 2 }
actsFailRedial OBJECT-TYPE SYNTAX INTEGER (0..9999) MAX-ACCESS read-only STATUS current
DESCRIPTION
“When the dial-up session fails to connect this is the time in seconds to wait to try again.”
::= { acts 3 }
actsMaxCallPeriod OBJECT-TYPE SYNTAX INTEGER (0..999) MAX-ACCESS read-only STATUS current
DESCRIPTION
“This is the maximum time in minutes the ACTS unit will wait between successful calls to the ACTS service.”
::= { acts 4 }
actsPhoneNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) MAX-ACCESS read-only
STATUS current
DESCRIPTION
“This is the phone number of the ACTS dial-up service, including any prefixes needed to reach an outside line or international dialing. Prefixes are separated by a comma from the main phone number.” ::= { acts 5 }
actsNumberOfCalls OBJECT-TYPE SYNTAX Counter MAX-ACCESS read-only STATUS current
DESCRIPTION
“Number of times the time server has called the ACTS dial-up service - weather the call was successful or not.”
::= { acts 6 }
6000-100AppD.fm Rev. D | TimeVault™ User’s Manual | D-121 |