Symmetricom SNMP Enterprise MIB

Appendix D: SNMP – Simple Network Management Protocol

actsBaudRate OBJECT-TYPE SYNTAX INTEGER

{

baud300 (300), baud1200 (1200),

baud9600 (9600),

}

MAX-ACCESS read-only STATUS current

DESCRIPTION

“Indicates the baud rate setting for the ACTS modem. The ACTS dial-up service accepts 300 or 1200 baud. Note: this is a rare case where faster is not better and 300 baud yields the best time accuracy.” ::= { acts 2 }

actsFailRedial OBJECT-TYPE SYNTAX INTEGER (0..9999) MAX-ACCESS read-only STATUS current

DESCRIPTION

“When the dial-up session fails to connect this is the time in seconds to wait to try again.”

::= { acts 3 }

actsMaxCallPeriod OBJECT-TYPE SYNTAX INTEGER (0..999) MAX-ACCESS read-only STATUS current

DESCRIPTION

“This is the maximum time in minutes the ACTS unit will wait between successful calls to the ACTS service.”

::= { acts 4 }

actsPhoneNum OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) MAX-ACCESS read-only

STATUS current

DESCRIPTION

“This is the phone number of the ACTS dial-up service, including any prefixes needed to reach an outside line or international dialing. Prefixes are separated by a comma from the main phone number.” ::= { acts 5 }

actsNumberOfCalls OBJECT-TYPE SYNTAX Counter MAX-ACCESS read-only STATUS current

DESCRIPTION

“Number of times the time server has called the ACTS dial-up service - weather the call was successful or not.”

::= { acts 6 }

6000-100AppD.fm Rev. D

TimeVault™ User’s Manual

D-121