Chapter 4: Serial or Telnet I/O Functions | Extended Function Commands |
4.4.1F100 BASET – 100
Use the BASET command to query the current
To query the maximum
F100<SP>BASET<Enter>
where
F | = | ASCII character F |
100 | = | unit function number |
<SP> | = | space |
BASET | = | specify |
<Enter> | = | input line terminator |
An example of the response is:
F100 BASET 100T
To set the maximum connection speed to
F100<SP>BASET<SP>100<Enter>
where: |
|
|
100 | = | set maximum |
To set the maximum connection speed to
F100<SP>BASET<SP>10<Enter>
where
10 | = | set maximum |
In both these cases, the unit responds:
Are you sure? (y/N)
As a safety feature, after sending this command, you have 10 seconds to respond affirmatively (enter the letter “y”) to the confirmation prompt, after which the unit executes the command and resets. Within that 10 second time period, any other response, including no response, results in the unit canceling the command.
For details about an initial
TimeVault™ User’s Manual |