Chapter 4: Serial or Telnet I/O Functions | Extended Function Commands |
4.4.3F100 EA – Ethernet Address
The Ethernet address is assigned at the factory. It is a fixed,
To request the Ethernet address of the unit NET Port, send the following command:
F100 EA<Enter>
The unit responds:
F100
where
F100
Attempts to set this field will be rejected with a syntax error message.
The F100 EA (and F36EA) command reports in the Ethernet address IEEE format, which may result in numbers which differ from those reported by your system. Since the Ethernet address is a fixed value, as long as the unit is up and running (you can ping the unit to be sure), you can safely ignore these differences.
4.4.4F100 IP – IP Address
To obtain the IP address of the unit NET Port, send the following command:
F100 IP<Enter>
The unit responds:
F100 IP:nnn.nnn.nnn.nnn<CR><LF>
where “nnn.nnn.nnn.nnn” is the dotted decimal address notation. An example of the response is:
F100 IP:206.54.0.33
Changing the IP Address requires the unit to reset. A verification prompt appears prior to execution.
To set the IP address and restart the unit, send the following command:
F100 IP:nnn.nnn.nnn.nnn<Enter>
Sample entry: | F100 IP:206.54.0.21<Enter> |
The response is: | Are you sure? (y/N) |
As a safety feature, after sending this command, you have 10 seconds to respond affirmatively (enter the letter “y”) to the confirmation prompt, after which the unit executes the command and resets. Within that 10 second time period, any other response, including no response, results in the unit canceling the command.
TimeVault™ User’s Manual |