![](/images/new-backgrounds/1121541/121541141x1.webp)
Function Commands | Chapter 4: Serial or Telnet I/O Functions |
You can see from the sample list below that “enabled”, “good”, and “tracked” satellites are “current”. That means that the unit does not use any satellite with questionable communication to calculate time, even if that satellite is enabled, visible and being tracked.
Sample entry: |
| F60<Enter> |
| |
The response is a current list, an example of which is: |
| |||
F60 | prn 1 | bad | enabled | sig level= +0.00 |
F60 | prn 2 | bad | enabled | sig level= +0.00 |
F60 | prn 3 | good | enabled tracked current sig level=+13.64 | |
F60 | prn 4 | bad | enabled | sig level= +0.00 |
F60 | prn 5 | bad | enabled | sig level= +0.00 |
F60 | prn 6 | good | enabled | sig level= +0.00 |
F60 | prn 7 | bad | enabled | sig level= +0.00 |
F60 | prn 8 | bad | enabled | sig level= +0.00 |
F60 | prn 9 | bad | enabled | sig level= +0.00 |
F60 | prn 10 | bad | enabled | sig level= +0.00 |
F60 | prn 11 | bad | enabled tracked | sig level= +3.00 |
F60 | prn 12 | bad | enabled | sig level= +0.00 |
F60 | prn 13 | bad | enabled | sig level= +0.00 |
F60 | prn 14 | bad | enabled | sig level= +0.00 |
F60 | prn 15 | good | enabled tracked current sig level=+22.77 | |
F60 | prn 16 | bad | enabled | sig level= +0.00 |
F60 | prn 17 | good | enabled | sig level= +0.00 |
F60 | prn 18 | bad | enabled | sig level= +0.00 |
F60 | prn 19 | bad | enabled | sig level= +0.00 |
F60 | prn 20 | bad | enabled tracked | sig level= +3.00 |
F60 | prn 21 | good enabled tracked current sig level=+20.15 | ||
F60 | prn 22 | good enabled | sig level= +0.00 | |
F60 | prn 23 | good | enabled tracked current sig level=+15.27 | |
F60 | prn 24 | bad | enabled | sig level= +0.00 |
F60 | prn 25 | bad | enabled tracked | sig level= +3.47 |
F60 | prn 26 | good | enabled | sig level= +0.00 |
F60 | prn 27 | bad | enabled | sig level= +0.00 |
F60 | prn 28 | bad | enabled | sig level= +0.00 |
F60 | prn 29 | good | enabled tracked current sig level=+21.46 | |
F60 | prn 30 | bad | enabled | sig level= +0.00 |
F60 | prn 31 | good | enabled tracked current sig level=+18.10 | |
F60 | prn 32 | bad | enabled | sig level= +0.00 |
TimeVault™ User’s Manual |