Chapter 4: Serial or Telnet I/O Functions | Extended Function Commands |
As a safety feature, after sending this command, you have 10 seconds to respond affirmatively (enter the letter “y”) to the confirmation prompt, after which the unit executes the command and resets. Within that 10 second time period, any other response, including no response, results in the unit canceling the command.
Unit example execution:
RESET BURN_DISABLE_BIT = 0
If you are in normal mode and you try to reset the burn host lock, you will get a friendly reminder:
Command Canceled
BURN_DISABLE_BIT = 1
Bootloader Mode Required
Reboot while holding SAVE key
4.4.24F100 PRESETALL - Password Reset All
Use Password Reset All when you want to set passwords back to the factory defaults.
PRESETALL is a
To reset all the passwords to factory defaults, send the following command:
F100 PRESETALL<Enter>
The unit responds:
Are you sure? (y/N)
If you answer “y” and press Enter, the unit executes the command.
As a safety feature, after sending this command, you have 10 seconds to respond affirmatively (enter the letter “y”) to the confirmation prompt, after which the unit executes the command and resets. Within that 10 second time period, any other response, including no response, results in the unit canceling the command.
Unit example execution:
Flash memory writing in progress:
Default user name and password set: 2
Default user name and password set: 1
4.4.25F100 PN - Password System User Name Change
Use Password System User Name when changing the login user name. To change the login user name, send the following command:
F100 PN<Enter>
The unit responds:
User Name Change for xyz123 Enter new user name:
TimeVault™ User’s Manual |