Chapter 4: Serial or Telnet I/O Functions

Function Commands

4.3Function Commands

4.3.1F03 – Time and Date Request

Use Function F03 to request time and date. The response is UTC date and time. To request TIME AND DATE, send the following command:

F03<Enter>

The unit responds:

F03<SP><mm>/<dd>/<yyyy><SP><HH>:<MM>:<SS><CR><LF>

where

F

=

ASCII character F

03

=

function number

<SP>

=

space

<mm>

=

one- or two-digit month

/

=

ASCII character slash

<dd>

=

one- or two-digit day

<yyyy>

=

four-digit year (if you manually entered this data)

<HH>

=

one- or two-digit hours

:

=

ASCII character for a colon

<MM>

=

two-digit minutes

<SS>

=

two-digit seconds

;

=

replacement character

<Enter>

=

input line terminator

<CR><LF>

=

output line terminator

Sample Entry:

F03<Enter>

The response might be:

F03 UTC 01/07/1996 02:48:29<CR><LF>

4.3.2F18 – Software Version Request

Use Version Request to query the software version number of the unit. The version number is factory set and cannot be changed. This command is for backwards compatibility and is identical to the F100 VER command (see page 4-66).