Automatic Gap Adjustment (AGA) |
|
| CSI ... + z |
| |||
Direct Setting of the Print Head Distance |
| CSI ... + y |
| ||||
|
|
|
|
|
|
|
|
Data Structure ASCII | CSI | n | "+" | "z" | [B] | automatic gap adjustment | ➊ |
hex. | 9B | n | 2B | 7A |
|
|
|
dec. | 155 | n | 43 | 122 |
|
|
|
ASCII | CSI | n | "+" | "y" | [B] | direct setting of the print head distance | ➋ |
hex. | 9B | n | 2B | 79 |
|
|
|
dec. | 155 | n | 43 | 121 |
|
|
|
Description ➊ For the sequence CSI n + z the following parameters are available for n:
n | hex. | dec. | Adjustment (automatic) |
|
|
|
|
0 | 30 | 48 | automatic adjustment OFF |
|
|
| (print head distance must be set at the printer) |
1 | 31 | 49 | automatic adjustment ON |
➋For the sequence CSI n + y the following parameters are available for n:
n | hex. | dec. | Setting (direct) |
|
|
|
|
0 | 30 | 48 | Default value |
|
|
| (is set at the printer) |
n |
|
| print head distance in n |
Setting the print head distance accords to the respective paper path selected. Unit, adjust range and default setting depend on the device used.
If the Automatic Gap Adjustment is set to ON, the sequence ➋ is ignored.
Example: |
|
|
Settings of T2060: | Unit = | 10 Micrometers |
| Adjust range = | 1 – 100 |
| Default value = | 18 |