Part IV

Sequencer

MEASURE COPY

Copy recorded data of specified measures to a specified point.

On the destination track, the new data replaces the current measure contents.

1.Specify the measures you wish to copy from

the source track (FROM).

On the FROM side, specify the settings with the corre- sponding buttons.

TRACK: Specify the track number you wish to copy the measures from.

You cannot select the track for the RHYTHM part or CHORD part in which a repeat command has been stored.

If ALL is selected, the specified measures are copied to all tracks at the same time.

FIRST MEAS: Specify the first measure to copy.

LAST MEAS: Specify the last measure to copy.

2.Specify where you wish to copy the selected

measures to.

On the TO side, specify the settings with the correspond-

ing buttons.

TRACK: Specify the track number you wish to copy to.

Measures in a track for the CONTROL, RHYTHM or CHORD part can be copied only to the same track.

START MEAS: Specify the start point to copy the selected measures to.

REPEAT: Specify the number of times the selected meas- ures are to be repeated.

3.Press the OK button.

The confirmation display appears. Press the YES button to execute the function, or press the NO button to cancel the function.

Note that if the END command is included in the source data, it is also copied. Any data following the END com- mand is not copied.

MEASURE ERASE

Erase the recorded contents of specific measures. You can also specify which type of data is to be erased.

Note that only the contents of the measures are erased, not the measures themselves; the length of the perform- ance remains the same.

1.Use the TRACK and buttons to specify

the track number.

This function does not work for the RHYTHM part or CHORD part in which a repeat command has been stored.

If ALL is selected, data is erased from the specified measures of all the tracks at one time.

2.Use the FIRST MEASURE and buttons to specify the start point (measure number).

3.Use the LAST MEASURE and buttons to specify the end point (measure number).

4.Use the ERASE DATA and buttons to

specify the type of data to be erased.

ALL: All data is erased.

NOTE: Only note data is erased.

CONTROL: Only control data (volume, effect and other panel settings as well as selection changes) is erased.

5.Press the OK button.

The confirmation display appears. Press the YES button to execute the function, or press the NO button to cancel the function.

MEASURE DELETE

Delete specified measures from a track.

The length of the performance accordingly decreases by the number of deleted measures.

1.Use the TRACK and buttons to select the

track from which measures are to be deleted.

This function does not work for the CHORD or RHYTHM track in which the repeat function has been stored.

If ALL is selected, the specified measures are deleted from all the tracks at one time.

2.Use the FIRST MEASURE and buttons, to specify the first measure to delete.

3.Use the LAST MEASURE and buttons to specify the last measure to delete.

4.Press the OK button.

The confirmation display appears. Press the YES button to execute the function, or press the NO button to cancel the function.