Application Examples
64 TDS1000/2000-Series Digital Oscilloscope User Manual
Triggering on Video Lines
Automatic. Youcan also look at the video lines in the field. To trigger
on the video lines, followthese steps:
1. Push the AUTOSET button.
2. Push the top optionbutton to select Line to sync on all l ines.
(The AUTOSET Menu includes All Li nes and Line Number
options.)
Manual. An alternative method requires more steps, but may be
necessary depending on the video signal. To use the method, follow
these steps:
1. Push the TRIG MENU button to see the Trigger Menu.
2. Push the top optionbutton and select Vi deo.
3. Push the Sync option button and select All Lines.orLine
Number andturntheUSER SELECT knob to set a specific line
number.
4. Push the Standard option button and select NTSC.
5. Turn the SEC/DIV knob to see a complete vi deo line across the
screen.
6. Turn the VOLTS/ DIV knob to ensure that the entire video signal
is visible on the screen.