TMS32020

SPRS010B Ð MAY 1987 Ð REVISED NOVEMBER 1990

absolute maximum ratings over specified temperature range (unless otherwise noted)²

Supply voltage range, VCC³

. ± 0.3

V to 7 V

Input voltage range

. ± 0.3

V to 7 V

Output voltage range

. ± 0.3

V to 7 V

Continuous power dissipation

. . . . . . . .

. . 2 W

Operating free-air temperature range

. . . 0°C to 70°C

Storage temperature range

± 55°C to 150°C

²Stresses beyond those listed under ªAbsolute Maximum Ratingsº may cause permanent damage to the device. This is a stress ratingonly, and functional operation of the device at these or any other conditions beyond those indicated in the ªRecommended Operating Conditionsº section of

this specification is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. ³ All voltage values are with respect to VSS.

recommended operating conditions

 

 

 

MIN

NOM

MAX

UNIT

 

 

 

 

 

 

 

VCC

Supply voltage

4.75

5

5.25

V

VSS

Supply voltage

 

0

 

V

VIH

High-level input voltage

All inputs except CLKIN

2

VCC + 0.3

V

CLKIN

2.4

VCC + 0.3

V

 

 

VIL

Low-level input voltage

All inputs except CLKIN

± 0.3

 

0.8

V

 

 

 

 

 

CLKIN

± 0.3

 

0.8

V

 

 

 

 

 

 

 

 

 

 

IOH

High-level output current

 

 

300

A

IOL

Low-level output current

 

 

2

mA

TA

Operating free-air temperature (see Notes 1 and 2)

0

 

70

°C

NOTES: 1. Case temperature (TC) must be maintained below 90°C. 2. RθJA = 36°C/Watt, RθJC = 6°C/Watt.

electrical characteristics over specified free-air temperature range (unless otherwise noted)

 

PARAMETER

TEST CONDITIONS

MIN

TYP§

MAX

UNIT

VOH

High-level output voltage

VCC = MIN, IOH = MAX

2.4

3

 

V

VOL

Low-level output voltage

VCC = MIN, IOL = MAX

 

0.3

0.6

V

IZ

Three-state current

VCC = MAX

±20

 

20

A

II

Input current

VI = VSS to VCC

±10

 

10

A

 

 

TA = 0°C, VCC = MAX, fx = MAX

 

 

360

mA

ICC

Supply current

TA = 25°C, VCC = MAX, fx = MAX

 

250

 

mA

 

 

TC = 90°C, VCC = MAX, fx = MAX

 

 

285

mA

CI

Input capacitance

 

 

 

15

pF

CO

Output capacitance

 

 

 

15

pF

§ All typical values for ICC are at VCC = 5 V, TA = 25°C.

ADVANCE INFORMATION

This device contains circuits to protect its inputs and outputs against damage due to high static voltages or electrostatic fields. These circuits have been qualified to protect this device against electrostatic discharges (ESD) of up to 2 kV according to MIL-STD-883C, Method 3015; however, it is advised that precautions should be taken to avoid application of any voltage higher than maximum-rated voltages to these high-impedance circuits. During storage or handling, the device leads should be shorted together or the device

should be placed in conductive foam. In a circuit, unused inputs should always be connected to an appropriated logic voltage level, preferably either VCC or ground. Specific guidelines for handling devices of this type are contained in the publication Guidelines for Handling Electrostatic-Discharge-Sensitive (ESDS) Devices and Assemblies available from Texas Instruments.