VIL
TA
Low-level input voltage
Operating free-air temperature
ICC Low-level input voltage TA = 0°C, VCC = MAX, fx = MAX mA
TMS320C25, TMS320E25
SPRS010B— MAY 1987— REVISED NOVEMBER 1990
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001 27
absolute maximum ratings over specified temperature range (unless otherwise noted)
Supply voltage range, VCC – 0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input voltage range: TMS320E25 pins 24 and 25 – 0.3 V to 15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . All other inputs – 0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output voltage range – 0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous power dissipation 1.5 W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating free-air temperature range 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Storage temperature range – 55°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only, and
functional operation of the device at these or any other conditions beyond those indicated in the “Recommended Operating Conditions” section of
this specification is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltage values are with respect to VSS.
recommended operating conditions
MIN NOM MAX UNIT
VCC Supply voltage 4.75 5 5.25 V
VSS Supply voltage 0 V
All inputs except CLKIN/CLKX/CLKR/INT (0-2) 2.35 VCC + 0.3 V
VIH High-level input voltage INT (0-2) 2.5 VCC + 0.3 V
CLKIN/CLKX /CLKR 3.5 VCC + 0.3 V
All inputs except MP/MC – 0.3 0.8 V
MP/MC – 0.3 0.8 V
IOH High-level output current 300 µA
IOL Low-level output current 2 mA
TMS320C25, TMS320E25 0 70 °C
TMS320C25GBA – 40 85 °C
electrical characteristics over specified free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP§MAX UNIT
VOH High-level output voltage VCC = MIN, IOH = MAX 2.4 3 V
VOL Low-level output voltage VCC = MIN, IOL = MAX 0.3 0.6 V
IZThree-state current VCC = MAX –20 20 µA
IIInput current VI = VSS to VCC –10 10 µA
Normal 110 185
Idle/HOLD 50 100
CIInput capacitance 15 pF
COOutput capacitance 15 pF
§All typical values are at VCC = 5 V, TA = 25°.
Caution. This device contains circuits to protect its inputs and outputs against damage due to high static voltages or electrostatic
fields. These circuits have been qualified to protect this device against electrostatic discharges (ESD) of up to 2 kV according to
MIL-STD-883C, Method 3015; however, it is advised that precautions to be taken to avoid application of any voltage higher than
maximum rated voltages to these high-impedance circuits. During storage or handling, the device leads should be shorted together
or the device should be placed in conductive foam. In a circuit, unused inputs should always be connected to an appropriate logic voltage level,
preferably either VCC or ground. Specific guidelines for handling devices of this type are contained in the publication “Guidelines for Handling
Electrostatic-Discharge Sensitive (ESDS) Devices and Assemblies” available from Texas Instruments
ADVANCE INFORMATION