TMS320E25

SPRS010B Ð MAY 1987 Ð REVISED NOVEMBER 1990

EPROM PROGRAMMING

absolute maximum ratings over specified temperature range (unless otherwise noted)²

Supply voltage range, VPP³

± 0.6 V to 15 V

Input voltage range on pins 24 and 25

± 0.3 V to 15 V

² Stresses beyond those listed under ªAbsolute Maximum Ratingsº may cause permanent damage to the device. This is a stress ratingonly, and functional operation of the device at these or any other conditions beyond those indicated in the ªRecommended Operating Conditionsº section of this specification is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.

³All voltage values are with respect to GND.

recommended operating conditions

 

 

MIN

NOM

MAX

UNIT

 

 

 

 

 

 

VCC

Programming mode supply voltage (see Note 13)

 

6

 

V

VCC

Read mode supply voltage

4.75

5

5.25

V

VPP

Programming mode supply voltage

12

12.5

13

V

VPP

Read mode supply voltage (see Note 12)

 

VCC

 

V

NOTES: 12. VPP can be connected to VCC directly (except in the program mode). VCC supply current in this case would be ICC + IPP. During programming, VPP must be maintained at 12.5 V (± 0.25 V).

13.VCC must be applied before or at the same time as VPP and removed after or at the same time as VPP. This device must not be inserted into or removed from the board when VPP or VCC is applied.

electrical characteristics over specified temperature range (unless otherwise noted)

 

PARAMETER

TEST CONDITIONS

MIN TYP§

MAX

UNIT

IPP1

VPP supply current

VPP = VCC = 5.25 V

 

100

A

IPP2

VPP supply current (during program pulse)

VPP = 13 V

30

50

mA

§ All typical values for ICC are at VCC = 5 V, TA = 25°C.

recommended timing requirements for programming, TA = 25°C, VCC = 6 V, VPP = 12.5 V

(see Notes 14 and 15)

 

 

 

 

 

 

 

 

MIN

NOM

MAX

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

tw(IPGM)

Initial program pulse duration

0.95

1

1.05

ms

tw(FPGM)

Final pulse duration

2.85

 

78.75

ms

tsu(A)

Address setup time

2

 

 

s

tsu(E)

 

 

setup time

2

 

 

s

E

 

 

 

tsu(G)

 

 

setup time

2

 

 

s

G

 

 

tdis(G)

Output disable time from

 

 

 

0

 

130¶

ns

G

 

 

ten(G)

Output enable time from

 

 

 

 

 

 

150¶

ns

G

 

 

 

tsu(D)

Data setup time

2

 

 

s

tsu(VPP)

VPP setup time

2

 

 

s

tsu(VCC)

VCC setup time

2

 

 

s

th(A)

Address hold time

0

 

 

s

th(D)

Data hold time

2

 

 

s

Value derived from characterization data and not tested.

NOTES: 14. For all switching characteristics and timing measurements, input pulse levels are 0.4 V to 2.4 V and VPP = 12.5 V ± 0.5 V during programming.

15. Common test conditions apply for tdis(G) except during programming.

ADVANCE INFORMATION

POST OFFICE BOX 1443 HOUSTON, TEXAS 77001

33

Page 33
Image 33
Texas Instruments TMS320 specifications Eprom Programming, See Notes 14, Vpp, IPP1, IPP2