TMS320C25-50

ADVANCE INFORMATION

SPRS010B Ð MAY 1987 Ð REVISED NOVEMBER 1990

RS, INT, BIO, AND XF TIMING

switching characteristics over recommended operating conditions (see Notes 3 and 16)

 

 

 

PARAMETER

MIN

TYP MAX

UNIT

 

 

 

 

 

 

 

 

 

t

CLKOUT1 low to reset state entered

 

22²

ns

d(RS)

 

 

 

 

 

 

 

 

td(IACK)

CLKOUT1 to

 

valid

± 5

7

ns

IACK

td(XF)

XF valid before falling edge of

 

 

Q ± 8

 

ns

STRB

 

 

²Value derived from characterization data and not tested. NOTES: 3. Q = 1/4 tc(C)

16.RS, INT, BIO are asynchronous inputs and can occur at any time during a clock cycle.

timing requirements over recommended operating conditions (see Notes 3 and 16)

 

 

 

 

 

 

 

 

MIN NOM

MAX

UNIT

 

 

 

 

 

 

 

 

 

 

tsu(IN)

 

 

 

 

 

 

setup before CLKOUT1 high

25

 

ns

INT,

 

BIO,

 

RS

 

th(IN)

 

 

 

 

 

 

hold after CLKOUT1 high

0

 

ns

INT,

 

BIO,

 

RS

 

t

 

 

 

 

fall time

 

8²

ns

INT,

 

BIO

 

f(IN)

 

 

 

 

 

 

 

 

 

 

tw(IN)

 

 

 

 

low pulse duration

tc(C)

 

ns

INT,

 

BIO

 

tw(RS)

 

low pulse duration

3tc(C)

 

ns

RS

 

²Value derived from characterization data and not tested. NOTES: 3. Q = 1/4 tc(C)

16.RS, INT, BIO are asynchronous inputs and can occur at any time during a clock cycle.

HOLD TIMING

switching characteristics over recommended operating conditions (see Note 3)

 

 

 

 

 

PARAMETER

MIN

TYP MAX

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

low after CLKOUT1 low

1 ²

11

ns

HOLDA

d(CIL-AL)

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

low to address high-impedance

 

0 ²

ns

HOLDA

 

dis(AL-A)

 

 

 

 

 

 

 

 

 

 

 

 

t

Address high-impedance after CLKOUT1 low

 

mode, see Note 17)

 

20 ²

ns

(HOLD

 

dis(CIL-A)

 

 

 

 

 

 

 

 

 

 

 

 

td(HH-AH)

 

high to

 

high

 

19

ns

HOLD

HOLDA

 

t

Address driven before CLKOUT1 low

 

mode, see Note 17)

 

8 ²

ns

(HOLD

 

en(A-CIL)

 

 

 

 

 

 

 

 

 

 

 

 

²Value derived from characterization data and not tested. NOTES: 3. Q = 1/4 tc(C)

17.A15-A0, PS, DS, STRB, and R/W timings are all included in timings referenced as ªaddressº.

timing requirements over recommended operating conditions (see Note 3)

 

 

 

MIN

NOM MAX

UNIT

 

 

 

 

td(C2H-H)

 

valid after CLKOUT2 high

 

Q ± 19

ns

HOLD

 

NOTE 3: Q = 1/4 tc(C)

 

 

38

POST OFFICE BOX 1443 HOUSTON, TEXAS 77001

Page 38
Image 38
Texas Instruments TMS320 specifications TsuIN Setup before CLKOUT1 high