Image 104

TL-WR702N

150Mbps Wireless N Nano Router

Figure 5-42 Advanced Security settings

¾Packets Statistic interval (5 ~ 60) - The default value is 10. Select a value between 5 and 60 seconds in the pull-down list. The Packets Statistic interval value indicates the time section of the packets statistic. The result of the statistic used for analysis by SYN Flood, UDP Flood and ICMP-Flood.

¾DoS protection - Enable or Disable the DoS protection function. Only when it is enabled, will the flood filters be effective.

¾Enable ICMP-FLOOD Attack Filtering - Enable or Disable the ICMP-FLOOD Attack Filtering.

¾ICMP-FLOOD Packets threshold: (5 ~ 3600) - The default value is 50. Enter a value between 5 ~ 3600 packets. When the current ICMP-FLOOD Packets numbers is beyond the set value, the router will start up the blocking function immediately.

¾Enable UDP-FLOOD Filtering - Enable or Disable the UDP-FLOOD Filtering.

¾UDP-FLOOD Packets threshold: (5 ~ 3600) - The default value is 50. Enter a value between 5 ~ 3600 packets. When the current UPD-FLOOD Packets numbers is beyond the set value, the router will start up the blocking function immediately.

¾Enable TCP-SYN-FLOOD Attack Filtering - Enable or Disable the TCP-SYN- FLOOD Attack Filtering.

¾TCP-SYN-FLOOD Packets threshold: (5 ~ 3600) - The default value is 50. Enter a value between 5 ~ 3600 packets. When the current TCP-SYN-FLOOD Packets numbers is beyond the set value, the router will start up the blocking function immediately.