Command Reference Guide

/C Connect

Establishes a bidirectional connection between two ports. For more information, see Section 7.1. There are two types of connections:

Resident Connect: If the /C command specifies only one port, your resident port will be connected to the specified port.

Third Party Connect: If the /C command specifies two ports, the unit will connect the two ports indicated. Third Party Connections can only be initiated by ports and accounts that permit Supervisor commands.

Notes:

If your user account does not permit Supervisor commands, you will only be allowed to connect to ports specifically allowed by that account.

If the user account permits Supervisor commands, you are allowed to connect to any port.

RS232 Ports are not allowed to create a Third Party connection to the Network Port. For example, Port 1 cannot connect Port 3 to the Network Port.

Availability: Supervisor / Non-Supervisor

Format: /C <x> [x] [Enter]

Where x is the number or name of the port(s) to be connected.

Response:

Verbose: "Connected xx." When a Resident Connection is initiated, the RSM will also display the Resident Disconnect Sequence.

Terse: 1

/CP Copy RS232 Port Parameters

Allows quick set-up when several RS232 ports will be configured with similar parameters. When the /CP command is invoked, the RSM will display a menu that can be used to copy parameters to RS232 ports. For more information and other command options, please refer to Section 5.9.

Availability: Supervisor Only

Format: /CP [Enter]

Response: Displays Copy Parameters Menu.

13-4