Operation

To enter or exit Power Save mode:

Press and hold the System button on the System Control Panel for one second.

After you release the System button, the System Control Panel screen and indicator lights will turn off.

You can also enter or exit Power Save mode on the System Settings menu by selecting Desired Mode and scrolling to PowerSave as shown in Figure 2-4.

Operate

[Advanced]

 

Figure 2-4Power Save Mode

Returning to

If an inverter/charger supplies power to the network, applying AC input

Operate mode

with utility power or generator power automatically returns the system to

 

Operate mode.

Safe Mode

 

CAUTION: Unexpected behavior

 

Before installing or removing a device on the network, put the network into Safe

 

mode. This prevents unexpected behaviour.

 

 

Characteristics

Selecting Safe mode stops the generator (if it is running) and puts the

 

System Control Panel (and all Xanbus-enabled devices) into Safe mode.

 

While in Safe mode, the System Control Panel remains powered,

 

“listening” to and reporting its status to the network. However, the ouptut

 

power of all Xanbus-enabled devices is disabled and all inverting,

 

charging, and generator starting activity stops. In Safe mode, the RS2000

 

will not pass AC.

2–8

975-0125-01-01