Invert Power Derating vs Ambient Temperature

The inverter/charger delivers up to 2000 watts continuous of sine wave output to 50 °C ambient temperature and 1500 watts continuous of sine wave output to 60 °C ambient temperature, derated linearly from 50 °C to 60 °C.

If the unit is in elevated ambient temperature above 50 °C, you are required to reduce power draw according to the Figure A-1to avoid over- temperature shutdown.

2000

 

 

 

 

 

 

 

 

1500

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

-20

-10

0

10

20

30

40

50

60

 

 

Ambient Temperature ( °C )

 

 

Figure A-1Inverter Output Power vs Ambient Temperature

Charger Mode

Charger output (bulk mode) is 100 amps DC to 50 °C ambient. In higher ambients, the charger will automatically derate (reduce output current) to maintain internal temperatures at a safe level. Output at 60 °C ambient is approximately 75 amperes.