Specifications
A–6 975-0125-01-01
Invert Power Derating vs Ambient Temperature
The inverter/charger delivers up to 2000 watts continuous of sine wave
output to 50 °C ambient temperature and 1500 watts continuous of sine
wave output to 60 °C ambient temperature, derated linearly from 50 °C to
60 °C.
If the unit is in elevated ambient temperature above 50 °C, you are
required to reduce power draw according to the Figure A-1 to avoid over-
temperature shutdown.
Charger Mode
Charger output (bulk mode) is 100 amps DC to 50 °C ambient. In higher
ambients, the charger will automatically derate (reduce output current) to
maintain internal temperatures at a safe level. Output at 60 °C ambient is
approximately 75 amperes.
Figure A-1
Inverter Output Power vs Ambient Temperature
-20
500
1000
1500
2000
-10 0 10 20 30 40 50 60
Ambient Temperature ( °C )