Troubleshooting

 

Table 4-4

Fault Messages

 

 

 

 

 

Fault

 

Fault

 

 

 

 

 

 

 

 

 

Number

Message

Type

Cause

Solution

 

 

 

 

 

 

 

 

F24

Reset the RS2000. If

Escalating

AC Under Voltage

Clear the fault and attempt

 

 

problem persists, call

Auto Fault.

Shutdown (Inverter

restart. If problem persists, call

 

 

customer service.

Must occur

AC output)

customer service.

 

 

 

3 times in

 

 

 

 

 

 

60 seconds

 

 

 

 

 

 

before

 

 

 

 

 

 

becoming

 

 

 

 

 

 

a manual

 

 

 

 

 

 

fault.

 

 

 

 

 

 

 

 

 

 

 

F25

Reset the RS2000. If

Escalating

Auxiliary Power

Clear the fault and attempt

 

 

problem persists, call

Auto Fault.

Supply Over Voltage

restart. If problem persists, call

 

 

customer service.

Must occur

Shutdown

customer service.

 

 

 

3 times in

 

 

 

 

 

 

30 seconds

 

 

 

 

 

 

before

 

 

 

 

 

 

becoming

 

 

 

 

 

 

a manual

 

 

 

 

 

 

fault.

 

 

 

 

 

 

 

 

 

 

 

F26

Reset the RS2000. If

Escalating

Auxiliary Power

Clear the fault and attempt

 

 

problem persists, call

Auto Fault.

Supply Under Voltage

restart. If problem persists, call

 

 

customer service.

Must occur

Shutdown

customer service.

 

 

 

3 times in

 

 

 

 

 

 

30 seconds

 

 

 

 

 

 

before

 

 

 

 

 

 

becoming

 

 

 

 

 

 

a manual

 

 

 

 

 

 

fault.

 

 

 

 

 

 

 

 

 

 

 

F29

Reset the RS2000. If

Manual

AC Backfeed

Clear the fault and attempt

 

 

problem persists, call

 

Shutdown

restart. If problem persists, call

 

 

customer service.

 

 

customer service.

 

 

 

 

 

 

 

 

F30

is too cold and has

Manual

Battery Under

Clear the fault and attempt one

 

 

shut down. See

 

Temperature Fault

restart. Try restart again when

 

 

guide.

 

 

ambient temperature is warmer

 

 

 

 

 

or gently warm the battery.

 

 

 

 

 

 

 

 

F40

Reset the RS2000. If

Manual

No IPC

Service required.

 

 

problem persists, call

 

communication

 

 

 

 

customer service.

 

 

 

 

 

 

 

 

 

 

 

975-0125-01-01