Introduction
Comprehensive Electronic Protection
RS2000 is approved to meet a number of safety standards including UL 458, 4th edition, and CSA C22.2 No. 107.1. See “Regulatory Approvals” on page
RS2000 is equipped with numerous protection features to ensure safe operation.
Protection feature | This feature… |
|
|
Battery | Keeps the battery voltage from getting too high in |
protection | charge mode. Shuts the inverter off in invert mode. |
|
|
Battery | Prevents inverter from discharging your batteries |
protection | too low. The inverter doesn’t run if battery voltage is |
| too low. |
|
|
Protects the unit from overheating by either derating | |
protection | (charge mode) or by shutting down (invert mode). |
| See “Invert Power Derating vs Ambient |
| Temperature” on page |
|
|
Automatic over load | Protects the unit from excessive loads. The unit will |
protection | provide 5000 watts (2.5 times of the rated load) for |
| up to 5 seconds, and then protect itself by shutting |
| down. See Specifications on page |
| information. |
|
|
Short circuit protection | Detects short circuits and protects the unit by |
| shutting it down. |
|
|