Introduction

Comprehensive Electronic Protection

RS2000 is approved to meet a number of safety standards including UL 458, 4th edition, and CSA C22.2 No. 107.1. See “Regulatory Approvals” on page A–5for more information.

RS2000 is equipped with numerous protection features to ensure safe operation.

Protection feature

This feature…

 

 

Battery over-voltage

Keeps the battery voltage from getting too high in

protection

charge mode. Shuts the inverter off in invert mode.

 

 

Battery under-voltage

Prevents inverter from discharging your batteries

protection

too low. The inverter doesn’t run if battery voltage is

 

too low.

 

 

Over-temperature

Protects the unit from overheating by either derating

protection

(charge mode) or by shutting down (invert mode).

 

See “Invert Power Derating vs Ambient

 

Temperature” on page A–6.

 

 

Automatic over load

Protects the unit from excessive loads. The unit will

protection

provide 5000 watts (2.5 times of the rated load) for

 

up to 5 seconds, and then protect itself by shutting

 

down. See Specifications on page A–2for more

 

information.

 

 

Short circuit protection

Detects short circuits and protects the unit by

 

shutting it down.

 

 

1–6