Operation

Operating in Charger Mode

WARNING: Explosive Gases

Review the “Important Safety Instructions” on page vii before operating the inverter/charger. During charging, batteries may generate explosive gases. Thoroughly ventilate the areas around the batteries and ensure that there are no sources of flames or spark in the vicinity.

Study all battery manufacturer’s precautions such as removing or not removing cell caps while charging and the recommended rates of charge.

Important: If you are charging a non-sealed battery, ensure there is sufficient distilled water in each cell. The battery acid should be at the level specified by the battery manufacturer. This helps prevent over-heating and purges excessive gases from the cells. Do not overfill. For a battery without cell caps, follow the manufacturer’s recharging instructions carefully.

To operate the RS2000 in charger mode from the front panel:

1.Connect AC input power.

The charger automatically starts up when qualified AC power is connected if the charger is enabled, or the charger is disabled but the Force Charge enable override is On. See “Force Charge” on page 3– 25.

The batteries are charged according to the two-stage or three- stage formula you have selected on the System Control Panel. (See “Battery Charging Reference” on page B–1for more information on two-stage or three-stage charging.)

You can interrupt the charge cycle any time you desire by disabling the charger from the System Control Panel or by pressing the Charger Enable button (on the front panel of the RS2000) so it is no longer illuminated.

To maintain optimal performance in flooded batteries, an occasional equalize cycle may be required. See “Operating in Equalization Mode” on page 2–16.

While the batteries are being charged, you can monitor which stage they are in from the front panel of the RS2000 or from the System Control Panel.

To operate the charger with the System Control Panel, refer to Chapter 3, “Configuration”.

2–14

975-0125-01-01