Troubleshooting

Table 4-3 provides a detailed description of the warning messages and solutions.

 

Table 4-3

Warning Messages

 

 

 

 

 

Warning

 

Warning

 

 

 

 

 

 

 

 

 

Number

Message

Type

Cause

Solution

 

 

 

 

 

 

 

 

 

W0

FET1 over-temp.

Automatic

FET1 Over

Ensure adequate ventilation

 

 

 

Check airflow

 

Temperature Warning

around the RS2000. Reduce the

 

 

 

around it.

 

 

AC loads.

 

 

 

 

 

 

 

 

 

W1

FET2 over-temp.

Automatic

FET2 Over

Ensure adequate ventilation

 

 

 

Check airflow

 

Temperature Warning

around the RS2000. Reduce the

 

 

 

around it.

 

 

AC loads.

 

 

 

 

 

 

 

 

 

W2

Bulk cap. over-temp.

Automatic

DC Bulk Capacitor

Ensure adequate ventilation

 

 

 

Check airflow

 

Over Temperature

around the RS2000. Reduce the

 

 

 

around it.

 

Warning

AC loads.

 

 

 

 

 

 

 

 

 

W3

Transf’r over-temp.

Automatic

Transformer Over

Ensure adequate ventilation

 

 

 

Check airflow

 

Temperature Warning

around the RS2000. Reduce the

 

 

 

around it.

 

 

AC loads.

 

 

 

 

 

 

 

 

 

W4

Battery over-temp.

Automatic

Battery Over

Check battery voltage and

 

 

 

Check battery

 

Temperature Warning

battery cable connections. Stop

 

 

 

settings.

 

 

charging, if necessary. Check

 

 

 

 

 

 

for excessive ambient

 

 

 

 

 

 

temperature and adequate

 

 

 

 

 

 

ventilation in the battery

 

 

 

 

 

 

compartment

 

 

 

 

 

 

 

 

 

W5

Over-temperature.

Automatic

Ambient Over

Ensure adequate ventilation

 

 

 

Check airflow

 

Temperature Warning

around the RS2000. Reduce

 

 

 

around it.

 

 

charge rate or AC load.

 

 

 

 

 

 

 

 

 

W6

Too many AC loads.

Automatic

AC Overload Warning

Turn off some AC loads.

 

 

 

Turn some off.

 

(AC OUPUT)

 

 

 

 

 

 

 

 

 

 

W7

You have enabled

Automatic

Auto Restart After

If in invert mode, the unit may

 

 

 

system restart after

 

Fault Feature Enabled.

start up unexpectedly.

 

 

 

faults.

 

(This parameter is not

 

 

 

 

 

 

accessible through the

 

 

 

 

 

 

System Control Panel.

 

 

 

 

 

 

In the future, this

 

 

 

 

 

 

feature may be

 

 

 

 

 

 

configurable with

 

 

 

 

 

 

advanced panels.)

 

 

 

 

 

 

 

 

 

 

W8

You have enabled

Automatic

Equalization Enabled

Make sure voltage sensitive

 

 

 

battery equalization.

 

Warning

loads are disconnected from

 

 

 

See manual.

 

 

batteries.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 