If the two-stage charge is enabled, the charger finishes the absorption charge but does not go to float mode because some battery manufacturers advise against floating their batteries. The RS2000 goes into a monitoring mode instead where the charger monitors the batteries but does not float them.
A new two-stage charge cycle will be initiated under the same conditions as for three-stage charging.