Configuration
975-0125-01-01 3–25
Eqz Volts
Full name Equalization voltage
Configurable setting This setting lets you set the desired equalization voltage. This menu is
displayed only if charger equalization is enabled. Select a setting based on
the battery manufacturer’s recommendation. For more information, see
“Battery Charging Reference” on page B–1.
Force Charge
Full name Force Charge
Configurable setting This setting forces the charger to be enabled (On) whenever you have
qualified AC or reacquired qualified AC. If Force Enabled is not on, you
must turn it to On using the System Control Panel.
When to use If you want the charger to automatically start when you connect to
qualified AC input.
Outcome The charger starts whenever qualified AC input appears.
Eqz Volts [15.8V]
Range of values Increment Default
13.5 to 15.8 VDC 0.1 volts 15.8 VDC
Force Charge [On]
Valu es De fau lt
On On
Off