| Configuration | |
Eqz Volts |
|
|
|
|
|
|
Full name | Equalization voltage |
|
|
|
| |
Configurable setting | This setting lets you set the desired equalization voltage. This menu is | |||||
| displayed only if charger equalization is enabled. Select a setting based on | |||||
| the battery manufacturer’s recommendation. For more information, see | |||||
| “Battery Charging Reference” on page | |||||
|
|
|
|
|
|
|
| Eqz Volts | [15.8V] |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Range of values |
| Increment |
| Default | |
|
|
|
|
|
|
|
| 13.5 to 15.8 VDC |
| 0.1 volts |
| 15.8 VDC | |
Force Charge |
|
|
|
|
|
|
|
|
|
|
|
| |
Full name | Force Charge |
|
|
|
| |
Configurable setting | This setting forces the charger to be enabled (On) whenever you have | |||||
| qualified AC or reacquired qualified AC. If Force Enabled is not on, you | |||||
| must turn it to On using the System Control Panel. | |||||
|
|
|
|
|
| |
| Force Charge | [On] |
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
| Values |
| Default |
|
|
|
|
|
|
|
|
|
|
| On |
| On |
|
|
|
|
|
|
|
|
|
|
| Off |
|
|
|
|
|
|
|
|
| |||
When to use | If you want the charger to automatically start when you connect to | |||||
| qualified AC input. |
|
|
|
| |
Outcome | The charger starts whenever qualified AC input appears. |