Battery Charging Reference
Charge Algorithm Graph
Bulk | Absorption | Float |
VA |
|
|
VG |
|
|
VF1 |
|
|
VF2 |
|
|
| TCV | TF |
IB | TA | |
|
| |
IH |
|
|
| Time |
|
Figure |
Charge Algorithm Definitions
Table B-1 Battery Defaults
Voltage |
| Flooded (or wet) | Gel | AGM | |
|
|
|
|
| |
VA |
| Absorption Voltage (VDC) | 14.4 | 14.4 | 14.3 |
VG |
| Gassing Voltage (VDC) | 13.5 | 13.8 | 13.45 |
VF1 |
| Float Voltage (VDC) | 13.5 | 13.8 | 13.45 |
VF2 |
| Float Exit Voltage (VDC) | 12.5 | 12.5 | 12.5 |
VE |
| Equalize Voltage (VDC) | 15.8 | NA | NA |
Current |
| Flooded (or wet) | Gel | AGM | |
|
|
|
|
| |
IB |
| Bulk Current (ADC) | 20% Ah | 20% Ah | 20% Ah |
IH |
| Absorption Exit Current (ADC) | 2% Ah | 2% Ah | 2% Ah |
IE |
| Equalize Current (ADC) | 10% Ah | NA | NA |