Configuration
975-0125-01-01 3–13
Power Share
Configurable setting Power Share is a configurable setting that you set to match to the breaker
rating on the AC input. This setting is used to ensure that the charger
limits its output to try to prevent nuisance tripping of the AC input
breaker due to the total current drawn by the charger and your other AC
loads. See also “Power Share” on page 2–20.
When to use Set the Power Share setting to match the AC input breaker. Use this
setting when connecting to an AC source. If using multiple AC sources
via an AC transfer switch, adjust this setting to the smaller AC breaker
size.
Outcome Setting the value higher than the AC source’s external breaker could
cause the external breaker to trip.
Equalize
Configurable setting This setting lets you enable or disable charger equalization, if the battery
type is flooded (or wet).
Equalization can be turned on (enabled) or off (disabled).
When to use Review the section, “Operating in Equalization Mode” on page 2–16
before adjusting this setting. This menu item is displayed if the battery
type allows equalization.
Power Share [10A]
Range of values Increment Default
5 to 50 amps 5 amp increments 30 amps
Equalize [Off]
Valu e De fau lt
On
Off Off