| Configuration | |
Power Share |
|
|
|
|
|
|
|
Configurable setting | Power Share is a configurable setting that you set to match to the breaker | ||||||
| rating on the AC input. This setting is used to ensure that the charger | ||||||
| limits its output to try to prevent nuisance tripping of the AC input | ||||||
| breaker due to the total current drawn by the charger and your other AC | ||||||
| loads. See also “Power Share” on page |
|
| ||||
|
|
|
|
|
|
|
|
| Power Share |
| [10A] |
|
|
|
|
|
|
|
|
|
|
|
|
| Range of values |
| Increment |
| Default | ||
|
|
| |||||
|
|
|
|
|
|
| |
| 5 to 50 amps |
| 5 amp increments |
| 30 amps | ||
|
|
|
|
|
|
| |
When to use | Set the Power Share setting to match the AC input breaker. Use this | ||||||
| setting when connecting to an AC source. If using multiple AC sources | ||||||
| via an AC transfer switch, adjust this setting to the smaller AC breaker | ||||||
| size. |
|
|
|
|
|
|
Outcome | Setting the value higher than the AC source’s external breaker could | ||||||
| cause the external breaker to trip. |
|
| ||||
Equalize |
|
|
|
|
|
|
|
Configurable setting | This setting lets you enable or disable charger equalization, if the battery | ||||||
| type is flooded (or wet). |
|
| ||||
| Equalization can be turned on (enabled) or off (disabled). | ||||||
|
|
|
|
|
| ||
| Equalize |
| [Off] |
|
|
|
|
|
|
|
|
|
|
|
|
Value
On
Off
Default
Off
When to use | Review the section, “Operating in Equalization Mode” on page |
| before adjusting this setting. This menu item is displayed if the battery |
| type allows equalization. |