Battery Charging Reference

Charging Algorithms (Formulas)

Battery Type

 

RS2000 charges flooded (or wet) lead-acid, gel, AGM (absorbed glass

 

mat), and custom batteries.

Flooded (or wet)

Flooded (or wet) batteries have removable battery caps for refilling with

 

distilled water and testing the electrolyte.

Gel

Gel batteries have the electrolyte in the form of a gel rather than a liquid

 

and do not require topping up. Gel batteries are sealed and the battery

 

caps are not removable.

AGM

AGM (absorbed glass mat) batteries are similar to gel batteries except that

 

the electrolyte is absorbed into a fiberglass matting.

Custom

Custom is configured by the dealer, factory, or service center for battery

 

types other than those listed above.

WARNING: Risk of battery damage

Since the RS2000 has only one battery type setting for all batteries connected to its bank, do not mix battery types. All connected batteries should be of one kind: Flooded (or wet) or Gel or AGM or Custom.

Charge Algorithm Stages

Three-stage charging

If three-stage charging is enabled, the RS2000 will charge batteries in a sequence known as three-stage charging. The charging voltage delivered to the battery depends on the battery:

type setting

temperature (by switch setting or battery temperature sensor)

state of charge

The three automatic stages are:

bulk

absorption

float

See Figure B-1for a graph of the three-stage charging profile.