Specifications

Charger Specifications

All charging specifications are at nominal conditions: ambient temperature of 77 °F (25 °C), 120 VAC, 60 Hz input, unless otherwise specified.

Table A-2Charger Specifications

Charging method

Three-stage charge (Bulk, Absorption, Float)

 

Two-stage charge (Bulk, Absorption)

 

The default charging method is three-stage.

 

 

Without a battery temperature

Three settings with the following temperature

sensor

values:

 

• Cool 50 °F (10 °C)

 

• Warm 77 °F (25 °C)

 

• Hot 104 °F (40 °C)

 

The default value for this setting is Hot, and it can

 

only be changed by a dealer, factory, or service

 

centre.

 

 

With a battery temperature

The temperature compensation coefficients on a

sensor

12 volt battery are as follows:

 

• Flooded: 27 mV × (25 °C – BTS °C)

 

• Gel: 27 mV × (25 °C – BTS °C)

 

• AGM: 21 mV × (25 °C – BTS °C)

 

 

Equalization cycle

Yes, manual via System Control Panel

 

 

Number of independent battery

1

banks

 

 

 

Battery bank size settings

50 – 2000 Ahr

 

 

Battery type settings

Flooded, AGM, Gel, Custom

 

 

Power factor corrected charging

Yes

 

 

AC input voltage

90 – 135 VAC

 

 

AC input frequency

60 Hz nominal, 55 – 65 Hz operating range

 

 

Minimum battery voltage

3.0 VDC

 

 

Maximum DC output voltage

16.0 VDC

 

 

Charger efficiency

≥ 85%

 

 

Input power factor at full

> 0.95

charge rate

 

 

 

Maximum charge current

100 A

 

 

975-0125-01-01

A–3

Page 105
Image 105
Xantrex Technology RS2000 manual Table A-2Charger Specifications