Specifications
975-0125-01-01 A–3
Charger Specifications

All charging specifications are at nominal conditions: ambient

temperature of 77 °F (25 °C), 120 VAC, 60 Hz input, unless otherwise

specified.

Table A-2

Charger Specifications

Charging method Three-stage charge (Bulk, Absorption, Float)
Two-stage charge (Bulk, Absorption)
The default charging method is three-stage.
Without a battery temperature
sensor Three settings with the following temperature
values:
Cool 50 °F (10 °C)
Warm 77 °F (25 °C)
Hot 104 °F (40 °C)
The default value for this setting is Hot, and it can
only be changed by a dealer, factory, or service
centre.
With a battery temperature
sensor The temperature compensation coefficients on a
12 volt battery are as follows:
Flooded: 27 mV × (25 °C – BTS °C)
Gel: 27 mV × (25 °C – BTS °C)
AGM: 21 mV × (25 °C – BTS °C)
Equalization cycle Yes, manual via System Control Panel
Number of independent battery
banks 1
Battery bank size settings 50 – 2000 Ahr
Battery type settings Floo ded, AGM, Gel, Custom
Power factor corrected charging Yes
AC input voltage 90 – 135 VAC
AC input frequency 60 Hz nominal, 55 – 65 Hz operating range
Minimum battery voltage 3.0 VDC
Maximum DC output voltage 16.0 VDC
Charger efficiency 85%
Input power factor at full
charge rate > 0.95
Maximum charge current 100 A