Specifications
Charger Specifications
All charging specifications are at nominal conditions: ambient temperature of 77 °F (25 °C), 120 VAC, 60 Hz input, unless otherwise specified.
Table A-2 Charger Specifications
Charging method | • |
| • |
| The default charging method is |
|
|
Without a battery temperature | Three settings with the following temperature |
sensor | values: |
| • Cool 50 °F (10 °C) |
| • Warm 77 °F (25 °C) |
| • Hot 104 °F (40 °C) |
| The default value for this setting is Hot, and it can |
| only be changed by a dealer, factory, or service |
| centre. |
|
|
With a battery temperature | The temperature compensation coefficients on a |
sensor | 12 volt battery are as follows: |
| • Flooded: 27 mV × (25 °C – BTS °C) |
| • Gel: 27 mV × (25 °C – BTS °C) |
| • AGM: 21 mV × (25 °C – BTS °C) |
|
|
Equalization cycle | Yes, manual via System Control Panel |
|
|
Number of independent battery | 1 |
banks |
|
|
|
Battery bank size settings | 50 – 2000 Ahr |
|
|
Battery type settings | Flooded, AGM, Gel, Custom |
|
|
Power factor corrected charging | Yes |
|
|
AC input voltage | 90 – 135 VAC |
|
|
AC input frequency | 60 Hz nominal, 55 – 65 Hz operating range |
|
|
Minimum battery voltage | 3.0 VDC |
|
|
Maximum DC output voltage | 16.0 VDC |
|
|
Charger efficiency | ≥ 85% |
|
|
Input power factor at full | > 0.95 |
charge rate |
|
|
|
Maximum charge current | 100 A |
|
|