Battery Charging Reference
975-0125-01-01 B–7
AC Reconnect SummaryIf AC is disconnected during charging, the charge stage after AC is
reconnected is indicated in Table B-2.
Table B-2
AC Reconnect Summary
Time Flooded (or wet) Gel AGM
∆TAAbsorption Timeout (hours) 6 6 6
∆TCV Constant Voltage Absorption Timeout (hours) 1 1 1
∆TFFloat Timeout (days) 21 21 21
∆TEEqualize Timeout (hours) 1 NA NA
Important: The custom battery factory defaults are the same as for an AGM
battery.
Charge Stage
Before AC Reconnect After AC Reconnect
Bulk Bulk
Absorption Float/No Float
Float/No Float Float/No Float
Equalize Float/No Float