IMUX Card

Inverse Multiplexer (IMUX) Card Settings

Table 7-1. IMUX Card Main Screen Options and Defaults

Parameter

 

 

User Options

 

 

 

 

STATE

idle

busy

 

DIRECTION

out

in

 

WAN

w1-1

w1-2

w2-1 w2-2 w3-1 w3-2 w4-1 w4-2

MAIN CHANNEL

01-23

01-30

99

N-CHANNELS

01-23

01-30

00

 

 

 

 

BONDING MODE

00-01

 

 

LAST DISC.

01-12

00

 

STATE

The State parameter shows the activity on this IMUX engine (port). The values are idle or busy.

DIRECTION

The Direction parameter shows the direction of a busy circuit. The values are out (a call originated from this location to another) or in (a call originated from another location).

WAN

The WAN parameter shows the WAN link used by the busy circuit. The values for this setting are w1-1through w4-2.

MAIN CHANNEL

The Main Channel parameter shows the timeslot on the WAN link shown on the previous setting that is used for the call to the IMUX primary number or hunt number for this call. Values for this setting are 1-24for T1 systems or 1-31for E1 systems. The value 99 is used for unassigned engines.

N-CHANNELS

The N-Channels parameter shows the number of additional timeslots needed to complete the IMUX call. The values for this setting are 1-23for T1 systems and 1-30for E1 systems. The value 00 is used for unassigned engines.

Server Cards

7-3

Page 193
Image 193