IMUX Card

Inverse Multiplexer (IMUX) Card Settings

Table 7-5. The HSU Card Dial Screen Settings and Options

Parameter

 

 

User Options

Default

 

 

 

PRIMARY #

up to 10 numeric characters

0000000000

HUNT GROUP #

up to10 numeric characters

0000000000

AUTO ANSWER

yes

no

 

 

yes

ANSWER TIMEOUT

01-60

 

 

 

01

DIAL TRIGGER

off

dtr

rs366

v.25b

off

 

 

 

 

 

 

ESCAPE CHAR

* #

5

6 7

9 0 00

*

IMUX PRIMARY #

up to 10 numeric characters

0000000000

IMUX HUNT #

up to 10 numeric characters

0000000000

 

 

 

IMUX ADD #

up to 10 numeric characters

0000000000

CURRENT PROFILE

none

loaded

 

none

PRIMARY #

The Primary Number is the main phone number used to route incoming (non-IMUX) calls for this HSU port. This number must be unique throughout all HSU ports in the system. The number must be within the range of numbers assigned by the carrier controlling the ISDN switch.

HUNT GROUP #

The Hunt Group number is an optional number that makes the port of this HSU part of a hunt group. The hunt group number is the same for all HSU ports in the hunt group. The system will route any incoming (non IMUX) call placed to the hunt group number to the first available HSU port in the group. A hunt group number must be within the range of numbers assigned by the carrier controlling the ISDN switch.

AUTO ANSWER

The Auto Answer feature allows the HSU port to automatically answer an incoming call for either the primary number or the hunt group number. A value of yes means the equipment will always accept the incoming call for a port that is not busy. A value of no means the HSU will not answer the call until the attached DTE responds with DTR high. RS530 ports will respond to auto answer with the Ring Indicator lead, V.35 ports must be set to auto answer for this version of the software.

ANSWER TIMEOUT

If the user chooses no for Auto Answer (above), the Answer Timeout parameter tells the system how long to wait for the DTE to raise DTR after the call has been sent to the DTE. This parameter is measured in seconds, and the valid choices are 1-60.

Server Cards

7-7

Page 197
Image 197
Zhone Technologies 600 HSU Card Dial Screen Settings and Options, Primary #, Hunt Group #, Auto Answer, Answer Timeout