FRS Card |
DCE PARAM
The DCE Parameters setting will show n/a unless a Port Type of
•Error Threshold (N392)
•Poll Verify Timer (T391)
•Events Counter (N393)
The Error Threshold (N392) counts the errors that will be tolerated during the cast number of events as set by the Events Counter before declaring the LMI link down. The number of errors options are 1 to 10. The value is input using the keyboard of the control terminal. The default is 3.
The Poll Verify Timer (T391) allows you to select the time interval (in seconds) that should elapse between “keep alive” messages sent from the corresponding DTE. The number of seconds options are 5 to 30. The default is 15 seconds.
The Events Counter (N393) allows you to select the window size for the number of events (frames) in which errors will be counted. If error threshold (N392) is exceeded within cast N393 frames, the link is declared down. The number of events counted are 1 to 10. The default is 4.
DTE PARAM
The DTE Parameters setting will show n/a unless a Port Type of
•Error Threshold (N392)
•Poll Interval Timer (T391)
•Events Counter (N393)
•Full Status Frequency (N391)
The Error Threshold (N392) counts the errors that will be tolerated during the cast number of events as set by the Events Counter before declaring the LMI link down. The number of errors options are 1 to 10. The value is input using the keyboard of the control terminal. The default is 3.
The Poll Verify Timer (T391) allows you to select the time interval (in seconds) that should elapse between “keep alive” messages sent from the corresponding DCE. The number of seconds options are 5 to 30. The default is 15 seconds.
Server Cards |